pybom
           Professional supplier and exporter of elevator parts


ningbo china elevator factory
 
Flat Traveling Cable

 

Flat Traveling Cable>>Model:TVVB

Part-No.
Type
No of cores
Specification
Width(MM)

Thickness
(MM)

Density Kg/Km
Shape
EKM 800 00
54
02
TVVB
2
0.75
8.0
4.6
69
EKM 800 00
54
03
TVVB
3
0.75
10.4
4.6
91
EKM 800 00
54
04
TVVB
4
0.75
13.7
4.6
119
EKM 800 00
54
05
TVVB
5
0.75
17.1
4.6
146
EKM 800 00
54
06
TVVB
6
0.75
19.4
4.6
168
EKM 800 00
54
07
TVVB
7
0.75
21.8
4.6
190
EKM 800 00
54
08
TVVB
8
0.75
24.1
4.6
212
EKM 800 00
54
09
TVVB
9
0.75
26.5
4.6
233
EKM 800 00
54
10
TVVB
10
0.75
28.8
4.6
255
EKM 800 00
54
11
TVVB
11
0.75
31.2
4.6
277
EKM 800 00
54
12
TVVB
12
0.75
33.5
4.6
299
EKM 800 00
54
13
TVVB
13
0.75
35.9
4.6
320
EKM 800 00
54
14
TVVB
14
0.75
39.2
4.6
348
EKM 800 00
54
15
TVVB
15
0.75
41.6
4.6
370
EKM 800 00
54
16
TVVB
16
0.75
43.9
4.6
392
EKM 800 00
54
17
TVVB
17
0.75
46.3
4.6
413
EKM 800 00
54
18
TVVB
18
0.75
49.6
4.6
441
EKM 800 00
54
19
TVVB
19
0.75
52.0
4.6
463
EKM 800 00
54
20
TVVB
20
0.75
54.3
4.6
485
EKM 800 00
54
21
TVVB
21
0.75
56.7
4.6
506
EKM 800 00
54
22
TVVB
22
0.75
59.0
4.6
528
EKM 800 00
54
23
TVVB
23
0.75
61.4
4.6
550
EKM 800 00
54
24
TVVB
24
0.75
64.7
4.6
578

 

Part-No.
Type
No of cores
Specification
Width(MM)

Thickness
(MM)

Density Kg/Km
Shape
EKM 800 00
54
24
TVVB
24
0.75
31.9
9.0
505
EKM 800 00
54
30
TVVB
30
0.75
40.7
8.3
627
EKM 800 00
54
36
TVVB
36
0.75
44.4
9.0
743
EKM 800 00
54
40
TVVB
40
0.75
51.8
8.3
805
EKM 800 00
54
42
TVVB
42
0.75
50.6
9.0
850
EKM 800 00
54
48
TVVB
48
0.75
56.7
9.0
957
EKM 800 00
54
54
TVVB
54
0.75
62.9
9.0
1065
EKM 800 00
54
60
TVVB
60
0.75
69.0
9.0
1172
EKM 800 00
54
66
TVVB
66
0.75
75.2
9.0
1279

Applications:

As control and signal cable for elevator as well as moving nachine parts, its bending radius is smaller compared with round cables due to the closely packed shielded cores or bundles, It can be installed in dry and damp rooms.

Properties:

The outer sheath is extensively resistant to oil and cooling liquid,
Standards: GB5023.6, IEC60227-6, EN50214

Structure:

Conductor: Fine strands of bare copper wire, acc. to VDE 0295,class 5
Insulation: special PVC
Colour: yellow, white, orange with black number with white digital coding
Bearing: steel rope
Outer Sheath: flexible PVC , cold resistance, flame resistance
Colour: Grey(RAL 7001)

Technical data:

Rated voltage:  300/500V 
Test voltage:  2500V  
Minimum bending radius: 0.3m≤L≤0.6M
Burning vertically test: GB/T1 8380.1-2001, IEC60332-1:1993 test passed

Used under the nomal conditions.the temperature of conductor is lower then 70
Temperature range:-15 to +70
TVVB (Parallel) free suspension length must not exceed 35 meters,and the lift speed 1.6m/s.
TVVB(interwist) free suspension length must not exceed 80 meters, and the life speed must not exceed 4m/s.

 

Copyright © Ningbo Beilun Elevator Technology Co., Ltd, All Rights Reserved. XML